UV-C sensor with lateral UV detection and digital interface
Features
- sensors are intended for monitoring UV lamps in water/air purification and disinfection systems
- detecting relative UV irradiance values
- UV values are indicated in "%" with the appropriate UV-monitor
- Positioned in a quartz tube in the centre of the circular lamp array they allow lateral "side-looking" detection of UV-C irradiation between the lamps of an reactor
- sensors cover the intensity range for low pressure application and incorporate an automated measuring range selection.
- due to the digital processsing the signal transmission is fail safe regardless of the cable length (max. 30m)
- connection of additional sensors to the RS485 bus allows multi sensor operation
- ModBus UV sensor types for connection to PLC are available on request
Technical Specification
supply voltage: | 12...24V DC |
---|---|
sensitive element: | silicon carbide diode (SiC) |
spectral range: | 210 - 380nm (220 - 290nm with UVC filter on request) |
aperture angle: | approx. 110° (laterally round) |
operation temperature: | 0 - 40°C (32 - 104°F) |
IP code: | IP40 |
body material: | stainless steel (sensor head: quartz glass) |
mounting: | to be mounted in a quartz tube |
dimensions: | sensor body: Ø20mm x 65mm sensor head: Ø14mm x 15mm total length (D-SLS-SiC006): 85mm |
wiring: | ready-to-use ZED sensor cables available in several lengths |
Display Units & Accessories
ZED UV Monitors
- UV Monitor PRO30D
- UV Monitor PRO11
- UV Monitor PRO16
ZED Radiometer
- SmartMeter
Control Units
- ZCONmini II
via RS485/ModBus RTU:
PLC or PCSensor PC-Software
- ZED Sensor Configurator