for analog and digital ZED UV-sensors
Features
- for use as UV-C monitoring system (displaying UV values in "W/m²", "mW/cm²" or "%")
- can be connected with
- up to two D-SiC UV-sensors with digital interface
- or one SiC-I UV-sensor with 4-20 mA signal output
- or one SiC UV-sensor with photodiode single - hour counter for operation hours and lamp replacement indication
- switchcycle counter
- system status indication:
- multicolor 2-line LCD
- green, red and yellow LCD backlight - system status forwarding:
- potential free relay contacts (UV alarm)
- UV value forwarding to PLC via 4-20 mA signal - ready for certification according to DVGW W294 and ÖNORM M5873
Technical Specification
supply voltage: | 230V AC ± 10% /45-65Hz (115V AC and 24V DC on request) |
---|---|
operation temperature: | max. 45°C (113°F) |
ambient temperature: | 0 - 40°C (32 - 104°F) |
IP code: | IP00 |
mounting: | to be installed in a closed cabinet |
dimensions (LxWxD): | 72,5 x 72,5 x 53 mm (2,85 x 2,85 x 2,08 inch) |
ZED UV-Sensors
- ...with digital interface
- ...with 4-20 mA interface
- ... with photodiode signal
Control Units
- via 4-20 mA signal output
- via relay contacts