Calibrated UV sensor with analog signal interface as plug-in sensor for UV systems in accordance with ÖNORM M5873-1 and pre-standard ÖNORM M5873-2.
Processing via PLC or ZED UV Monitor in “W/m²”, “mW/cm²” or in “%”
Recalibration is carried out by ZED,
optional: “in-field recalibration” for OEM customers for on-site recalibration using ZED SmartMeter without an external service provider
Features
- certified by an ÖNORM accredited laboratory
- available for low pressure and medium pressure applications
- customer specific adjustment: The analog signal output is preset according to customers specification (e.g. 100W/m² ≙ 10V)
- all digital UV-sensors are adjusted to cover the complete specified measurement range - low pressure types: range 2...500W/m² - medium pressure types: range 20...3000W/m² - customized ranges are available on request
- optionally with current or voltage interface - sensors incorporate internal digital signal processing and an integrated signal converter for the appropriate analog industrial interface for optimal operation with analog PLC
- to be used with an ÖNORM-compliant measurement window (e.g. ZED MF001)
Technical Specification
supply voltage: | 12...24V DC |
---|---|
sensitive element: | silicon carbide diode (SiC) |
spectral range: | 210 - 290nm |
operation temperatur: | 0 - 60°C (32 - 140°F) |
max. pressure / IP code: | not waterproof without measurement window MF001 IP64 on terminal ends if connected to appropriate sensor cable |
body material: | stainless steel 1.4305 |
mounting: | use with MF001 (pipe thread ISO228 G1) |
wiring: | ready-to-use ZED sensor cables available in several lengths |