analog 1/4-inch UV sensor
Features
- sensors are intended for monitoring UV lamps in water/air purification and disinfection systems
- for detecting absolute UV irradiance values
- UV values are indicated in "W/m²", "mW/cm²" or "%" with the appropriate UV-monitor via 4-20mA, 0-2V or 0-10V interface
- sensors incorporate internal digital signal processing and an integrated signal converter for the appropriate analog industrial interface for optimal operation with analog PLC
- all digital UV-sensors are adjusted to cover the complete specified measurement range - low pressure types: range 2...500W/m² - medium pressure types: range 20...3000W/m² - customized ranges are available on request
- customer specific adjustment: the analog signal output is preset according to customers specification (e.g. 7W/m² ≙ 10V)
- output value adaptation by customer: According to the special needs on location the reference UV value for analog signal output can be adapted by customer via ZED SmartMeter or Sensor Configurator PC software (e.g. set 75W/m² ≙ 10V)
Technical Specification
supply voltage: | 12...24V DC |
---|---|
sensitive element: | silicon carbide diode (SiC) |
spectral range: | 210 - 380nm (220 - 290nm with UVC filter on request) |
operation temperatur: | 0 - 60°C (32 - 140°F) |
max. pressure / IP code: | 10bar at front / IP64 on terminal ends if connected to appropriate sensor cable |
body material: | stainless steel 1.4404 |
mounting: | pipe thread ISO228 G¼ (use MF001-A to adapt to G1) |
wiring: | ready-to-use ZED sensor cables available in several lengths |
Display Units & Accessories
- ZED UV Monitors
- UV Monitor PRO11
- UV Monitor PRO16
- Radiometer
- SmartMeter
- Accessories
- Measurement Window Adapter MF001-A
- Sensor PC-Software