ballast with parameter adjustment and remote control for 4-pin UV-lamps, lamp power up to 600W
lamp power: up to 600 W
lamp current: up to 6,0 A
Features
- preheat start ballasts for optimal lamp operation with adjustable operation parameters
- single device - powers one lamp
- adjustable preheat and operation parameter settings for use in different environmental conditions
- controllable via PLC or ZED ZCON control units, allows dimming, using remote mode the status relay wiring can be omitted
- lamp and ballast status indication
- green, red and yellow LEDs
- potential free relay contacts
- ModBus/ZCON status request - up to 30 m lamp cable length possible, constant lamp and preheat current even with long cables
- local operation and digital remote control
- lamp operation control via RS485 using ModBus or ZCON protocol
- rack mounting ballasts
- less space for more ballasts
- push-in cards for quick servicing - enhanced protection
- power range control
- undervoltage protection
- overtemperature protection - high efficiency
- active power factor correction (PFC)
low THD according to EN 61000
Technical Specification
supply voltage: | 230 V AC ± 10% / 45-65 Hz (115 V AC types on request) |
---|---|
efficiency: | > 90% |
operation temperature: | max. 50 ° C (122 ° F) at TC-point (ballasts are overtemperature protected) |
ambient temperature: | 0 - 40 ° C (32-104 ° F) |
IP code: | IP00 |
dimensions (LxWxD): | 220 x 143,5 x 60 mm (8,66 x 5,65 x 2,36 inch) |
UV lamp types
- GPHHA1554T10L
- NNI 400/147 XL
- NNI 600/147 XL*
* special application
(ballasts for other UV lamp types available on request)
ZED Control Units
- ZCONmini
- ZCONdin
- ZCONnano
- ZCONsub