ballast with parameter adjustment and remote control for two 4-pin UV-lamps, lamp power up to 600W
lamp power: up to 600 W
lamp current: up to 6,0 A
Features
- preheat start ballasts for optimal lamp operation with adjustable operation parameters
- double device - powers two lamps, independent lamp operation even if one lamp is defective or disconnected
- adjustable preheat and operation parameter settings for use in different environmental conditons
- controllable via PLC or ZED ZCON control units, allows dimming, using remote mode the status relay wiring can be omitted
- lamp and ballast status indication - green, red and yellow LEDs - ModBus/ZCON status request - optional: potential free relay contacts
- up to 30 m lamp cable length possible
- local operation and digital remote control
- lamp operation control via RS485 using ModBus or ZCON protocol, optional: - ethernet interface - dimming using analog 4...20mA/0...10V interface
- rack mounting ballasts - less space for more ballasts - front accessible push-in contacts for quick installation
- enhanced protection - power range control - undervoltage protection - overtemperature protection
- high efficiency
- active power factor correction (PFC) low THD according to EN 61000
Technical Specification
supply voltage: | 230 V AC ± 10% / 45-65 Hz (115 V AC types on request) |
---|---|
efficiency: | > 90% |
operation temperature: | max. 50 ° C (122 ° F) at TC-point (ballasts are overtemperature protected) |
ambient temperature: | 0 - 40 ° C (32-104 ° F) |
IP code: | IP00 |
dimensions (LxWxD): | 270 x 250 x 70 mm (10.61 x 9.82 x 2.75 inch) |
UV lamp types
- GPHHA1554T10L
- NNI 400/147 XL
- NNI 600/147 XL*
* special application
(ballasts for other UV lamp types available on request)
ZED Control Units
- ZCONmini
- ZCONdin
- ZCONnano
- ZCONsub