ballast with parameter adjustment and remote control for 4-pin UV-lamps, lamp power up to 600W

lamp power: up to 600 W

lamp current: up to 6,0 A

Features

  • preheat start ballasts for optimal lamp operation with adjustable operation parameters
  • single device - powers one lamp
  • adjustable preheat and operation parameter settings for use in different environmental conditions
  • controllable via PLC or ZED ZCON control units, allows dimming, using remote mode the status relay wiring can be omitted
  • lamp and ballast status indication
    - green, red and yellow LEDs
    - potential free relay contacts
    - ModBus/ZCON status request
  • up to 30 m cable length possible, constant lamp and preheat current even with long cables
  • local operation and digital remote control
  • lamp operation control via RS485 using ModBus or ZCON protocol
  • metal housing, designed for optimal thermal flow
  • push-in contacts for quick installation
  • enhanced protection
    - power range control
    - undervoltage protection
    - overtemperture protection
  • high efficiency
  • active power factor correction (PFC)
    low THD according to EN 61000

Technical Specification

supply voltage: 230 V AC ± 10% / 45-65 Hz
efficiency: >90%
operation temperature: max. 50°C (122°F) at TC-point (ballasts are overtemperature protected)
ambient temperature: 0 - 40°C (32 - 104°F)
IP code: IP20
dimensions (LxWxD): 248 x 150 x 59 mm (9.76 x 5,89 x 2.32 inch)

UV lamp types

  • GPHHA1554T10L
  • NNI 400/147 XL
  • NNI 600/147 XL *

* special application

(ballasts for other UV lamp types available on request)

ZED Control Units

  • ZCONmini
  • ZCONdin
  • ZCONnano
  • ZCONsub