for analog and digital ZED UV-sensors

Features

  • for use as UV-C monitoring system (displaying UV values in "W/m²", "mW/cm²" or "%")
  • can be connected with - up to two D-SiC UV-sensors with digital interface - or one SiC-I UV-sensor with 4-20 mA signal output - or one SiC UV-sensor with photodiode single
  • hour counter for operation hours and lamp replacement indication
  • switchcycle counter
  • system status indication: - multicolor 2-line LCD - green, red and yellow LCD backlight
  • system status forwarding: - potential free relay contacts (UV alarm) - UV value forwarding to PLC via 4-20 mA signal
  • ready for certification according to ÖNORM M5873-1:2020-01-01 and DIN 19294-1: 2020-08

Technical Specification

supply voltage: 230V AC ± 10% /45-65Hz (115V AC and 24V DC on request)
operation temperature: max. 45°C (113°F)
ambient temperature: 0 - 40°C (32 - 104°F)
IP code: IP00
mounting: to be installed in a closed cabinet
dimensions (LxWxD): 72,5 x 72,5 x 53 mm (2,85 x 2,85 x 2,08 inch)

ZED UV-Sensors

  • ...with digital interface
  • ...with 4-20 mA interface
  • ... with photodiode signal

Control Units

  • via 4-20 mA signal output
  • via relay contacts
  •