temperature sensors with digital interface RS485 using ModBus or ZCON protocol

Features

  • temperature sensors are intended for temperature measurement in connection with UV monitoring in water/air purification and disinfection systems
  • 1/4 inch UVC-sensors
  • sensors can be mounted in the reactor wall pointing to the lamp like UV sensors
  • due to the digital processsing the signal transmission is fail safe regardless of the cable length (up to 30m)
  • Multi sensor operation of digital sensors is possible even with UV sensors by connecting additional sensors to the RS485 bus
  • ModBus temperature sensor types for connection to PLC are available on request

Technical Specification

supply voltage: 12...24V DC
sensitive element: KTY81-110
operation temperature: 0...85°C
max. pressure / IP code: 10bar at sensor front / IP64 on terminal ends if connected to appropriate sensor cable
body material: stainless steel
mounting: pipe thread ISO228 G¼ (use MF001-A to adapt to G1)
wiring: ready-to-use ZED sensor cables available in several lengths

ZED UV Monitors

  • PRO30D-I
  • PRO30D-U

ZED Control Units

  • ZCONmini
  • ZCONdin
  • ZCONsub
  • SPS/PLC
  • PC